• Àüü
  • ÀüÀÚ/Àü±â
  • Åë½Å
  • ÄÄÇ»ÅÍ
´Ý±â

»çÀÌÆ®¸Ê

Loading..

Please wait....

±¹³» ³í¹®Áö

Ȩ Ȩ > ¿¬±¸¹®Çå > ±¹³» ³í¹®Áö > Çѱ¹ÀÎÅͳÝÁ¤º¸ÇÐȸ ³í¹®Áö

Çѱ¹ÀÎÅͳÝÁ¤º¸ÇÐȸ ³í¹®Áö

Current Result Document :

ÇѱÛÁ¦¸ñ(Korean Title) »öä ȯ°æ ±â¹ÝÀÇ ÀÎü ¹ÝÀÀ Á¤º¸ ÃøÁ¤ ½Ã½ºÅÛ
¿µ¹®Á¦¸ñ(English Title) A Measurement System for Color Environment-based Human Body Reaction
ÀúÀÚ(Author) ±èÁö¾ð   Á¤Ã¢¿ø   ÁÖ¼öÁ¾   Ji-Eon Kim   Chang-Won Jeong   Su-Chong Joo  
¿ø¹®¼ö·Ïó(Citation) VOL 17 NO. 02 PP. 0059 ~ 0065 (2016. 04)
Çѱ۳»¿ë
(Korean Abstract)
»öä ȯ°æ¿¡ µû¶ó ÀÎÁö¹ÝÀÀÀÇ »ó°ü°ü°è¸¦ ºÐ¼®ÇÑ °á°ú°¡ ´Ù¾çÇÑ »ê¾÷ºÐ¾ß¿¡ Àû¿ëµÇ°í ÀÖ´Ù. ƯÈ÷, ÀÇÇÐ ºÐ¾ß¿¡¼­ »öä ȯ°æ±â¹Ý »ýü½ÅÈ£¸¦ ¼öÁýÇÏ¿© ȯÀÚ »óÅÂÀÇ Æľǰú Ä¡·á ±×¸®°í ³úÈ°µ¿ÀÇ ±Ô¸í¿¡ °ü·ÃµÈ ¿¬±¸°¡ È°¹ßÇÏ°Ô ÁøÇàµÇ°í ÀÖ´Ù. ±×·¯³ª ±âÁ¸ ¿¬±¸µéÀº »öäÁ¶¸í ¶Ç´Â LED¸¦ ÀÌ¿ëÇÑ »öä ȯ°æÀ» ±¸ÃàÇÏ¿© ´Ù¾çÇÑ ½ÇÇèÀ» ÁøÇàÇÏ°í ÀÖÀ¸³ª ´Ù¸¥ ±¤¿ø¿¡ ³ëÃâ µÇ¾î ½É¸®ÀûÀÎ ¿µÇâÀ» ÁÖ´Â ¹®Á¦Á¡À» °®°í ÀÖ´Ù. µû¶ó¼­, º» ³í¹®¿¡¼­ Á¦¾ÈÇÏ´Â ½Ã½ºÅÛÀº HMD(Head-Mounted-Display)¸¦ ÀÌ¿ëÇÏ¿© ÇÇÇèÀÚ¿¡°Ô ¿Ïº®ÇÑ »öä ȯ°æÁ¶°ÇÀ» Á¦°øÇÏ°íÀÚ ÇÑ´Ù. ±×¸®°í ÀÎü¹ÝÀÀÁ¤µµ ÃøÁ¤À» À§ÇØ ±â¾ï·Â-ÁÖÀÇ·Â Å×½ºÆ®ÇÏ´Â µ¿¾È BMS(Bio-Medical-System)À¸·Î »ýüÁ¤º¸¸¦ ¼öÁýÇÏ¿© »ö亰ÀÎü¹ÝÀÀÁ¤µµ ÃøÁ¤»Ó¸¸ ¾Æ´Ï¶ó ½É¸®ÀûÀÎ º¯È­¿¡ ´ëÇÑ »ó°ü°ü°è¸¦ È®ÀÎÇÒ ¼ö ÀÖ´Â ½Ã½ºÅÛÀ» Á¦¾ÈÇÑ´Ù. Á¦¾ÈÇÑ ½Ã½ºÅÛÀ» ÅëÇÏ¿© ¼öÁýÇÏ´Â »ýüÁ¤º¸´Â ½ÉÀüµµ(ECG), È£Èí(Respiration), »ê¼ÒÆ÷È­µµ(SpO2), ÀÓÇÇ´ø½º(Bio-Impedance), Ç÷¾Ð(Blood-Pressure) ÀÌ¸ç µ¥ÀÌÅͺ£À̽º¿¡ ÀúÀåÇÑ´Ù. ÀÌ¿ÍÇÔ²², ÀÎüÀÇ ÀÎÁö¹ÝÀÀÀ» ÃøÁ¤ÇϱâÀ§ÇØ ±â¾ï·Â-ÁÖÀÇ·Â Å×½ºÆ®´Â ¾ÛÀ¸·Î ±¸ÇöÇÏ¿© »öä Á¶°Çº° ÀÎÁö¹ÝÀÀ Á¤º¸¸¦ ÃøÁ¤ÇÏ°í °á°ú¸¦ È®ÀÎ ÇÒ ¼ö ÀÖ´Ù. Á¦¾ÈÇÑ ½Ã½ºÅÛÀ» ÅëÇÏ¿© ¼öÁýµÈ ÀÎü¹ÝÀÀÁ¤º¸¸¦ È°¿ëÇÏ¿© »ý¸®ÇÐÀû Á¤º¸ÀÇ Á¤·®È­ÇÏ´Â ¿¬±¸¸¦ ÁøÇàÇÒ ¼ö ÀÖÀ¸¸ç, »öä ȯ°æ°ú »ý¸®ÇÐÀû Á¤º¸ÀÇ »ó°ü°ü°è¸¦ ºÐ¼®ÇÏ¿© ÀÇÇÐÀû Áø´Ü ¹× Ä¡·á¿¡ ÀÀ¿ëÀÌ µÉ °ÍÀ¸·Î ±â´ëÇÑ´Ù. ÇâÈÄ ¿¬±¸·Î ±¸ÃàÇÑ ½Ã½ºÅÛÀ» ÅëÇØ ¼öÁýµÈ µ¥ÀÌÅ͸¦ ºÐ¼® ¹× ½Ã°¢È­ ±â´ÉÀ» Ãß°¡ÇÏ°í, Ä¡¸Å ÁúȯÀÇ ¿¹Ãø ¹× Ä¡·á¸¦ À§ÇÑ ½Ã½ºÅÛÀ¸·Î È®ÀåÇÏ¿© ÀçÈ°ÇÁ·Î±×·¥À¸·Î¼­ÀÇ À¯È¿¼ºÀ» Æò°¡ÇÏ°íÀÚ ÇÑ´Ù.
¿µ¹®³»¿ë
(English Abstract)
The result of analyzing the cognitive reaction due to the color environment has been applied to various filed especially in medical field. Moreover, the study about the identification of patient's condition and examination the brain activity by collecting the bio-signal based on the color environment is being actively conducted. Even though, there were a variety of experiments by convention the color environment using a light or LED color, it still has a problem that affects the psychological information. Therefore, our proposed system using a HMD (Head Mounting display) to provide a completed color environment condition. This system uses the BMS(Biomedical System) to collect the biometric information which responds to the specific color condition and the human body response information can be measured by the development the Memory and Attention test on Mobile phone. The collection of Biometric information includes electro cardiogram(ECG), respiration, oxygen saturation (Sp02), Bio-impedance, blood pressure will store in the database. In addition, we can verify the result of the human body reaction in the color environment by Memory and Attention application. By utilizing the reaction of the human body information that is collected thought the proposed system, we can analyze the correlation between the physiological information and the color environment. And we also expect that this system can apply to the medical diagnosis and treatment. For future work, we will expand the system for prediction and treatment of Alzheimer disease by analyzing the visualization data through the proposed system. We will also do evaluation on the effectiveness of the system for using in the rehabilitation program.
Å°¿öµå(Keyword) ÀÇ·á½Ã½ºÅÛ   »ýüÁ¤º¸   ÇコÄɾ »öä ȯ°æ   ¿þ¾î·¯ºí µð¹ÙÀ̽º   ½º¸¶Æ®µð¹ÙÀ̽º   Medical System   Bio-Signal   Health-Care   Color Environment   Wearable Device   Smart Device  
ÆÄÀÏ÷ºÎ PDF ´Ù¿î·Îµå